fully radiolucent patient monitoring kits
for use in the NICU & PICU
CLARAVUE is the best-in-class, hygienic solution for simple, accurate and fully radiolucent patient monitoring. Our selection of electrodes for the NICU / PICU are lightweight, disposable and prewired to eliminate motion artifact.
Claravue Features
Invisible Wires & Electrodes
No image obstruction under x-ray and fluoroscopy
Invisible under x-ray and fluoroscopy, CLARAVUE’s radiolucent leadwires allow for outstanding imaging during procedures in the Catherization Lab or Electrophysiology Department. Notably, CLARAVUE’s carbon wiring of electrodes does not appear under imaging equipment.
Quality Trace
Pre-wired electrodes eliminate the need to snap leadwires onto electrodes.
CLARAVUE’S best-in-class electrodes reduce motion artifact associated with movement of the leadwires on electrode snaps. Repositionable, disposable patient kits can be used for up to 5-days.
Quick Patient Hookup
Patented quick connection point, repositionable and comfortable
CLARAVUE’S patented quick connection consolidates standard 10 leadwire ends to two simple, plug-style connections. Reduce opportunities for error by simplifying connections. Lightweight and conforming cables increase patient comfort.
Disposable & Hygienic
Single Patient Use - Up to 5 Day Wear Time
Each completely disposable Patient Kit ensures the most hygienic solution for infection control.
CLARAVUE Packaging
CLARAVUE comes packaged in a dispenser case designed for easy storage and efficient product retrieval. Each patient kit is a single-use pack, containing all prewired electrodes.
Instructions For Use
Prep
Standard protocol for skin prep applies.
Open
Open the single CLARAVUE patient kit. Remove inner bag. Unwind sets from the holder card.
Peel
Gently remove electrode sets from release liner by peeling away from thumb tab.
Apply
Adhere the RA and RL electrode positions to the patient. Continue to apply set A across the patient’s chest to the LA position and down to the LL position. Repeat with set B, applying the V positions from left to right. CLARAVUE is repositionable, allowing the freedom to rearrange on the patient as necessary. Note: Gently pull the wire from the ribbon cable to expand the overall size of the set(s).
Insert
While holding the male end of the adapter (clear clip) attached to set A, align with the blue, triangular indicator. Press firmly until lever snaps. Repeat with the blue clip attached to set B.
5 Day Wear
Ensure a good signal is achieved on the monitor. If a standard three lead trace is necessary, unplug set B from the adapter cable and remove the corresponding V positions from the patient. CLARAVUE’s various lead configurations enables total hospital standardization.