Grounding Pads
Neutral Electrodes
Hydrogel Technology
Strong but gentle hydrogel adhesive provides immediate and steady impedance upon skin contact.
Skin Compatibility
Gel and adhesive foam are tolerated even by sensitive skin. There is no gel residue left on the skin after application.
Reduced Edge Effect
Rounded edges remove heavily concentrated areas of current thus reducing the chance of patient burns.
Adhesive Foam Border
The highly flexible adhesive foam border and the conductive gel ensures that the electrode will stay secure.
TWINSAFE GROUNDING PADS
(Diathermy Pads / Neutral Electrodes)
The revolutionary "sling design" of the TWIN-SAFE makes it possible for the first time to use efficiently the symmetry surveillance of last-generation devices fully and completely and with arbitrary electrode orientation. The typical symmetry deviation of the HF current is below 5 % with any orientation of the TWIN-SAFE.
SWAROPLATE Split Grounding Pads
(Diathermy Pads / Neutral Electrodes)
These electrodes are for applications with HF - surgery devices which support a Contact Quality Monitoring (CQM)
SWAROPLATE Non-Split Grounding Pads
(Diathermy Pads / Neutral Electrodes)
These electrodes are for standard applications with HF - surgery devices which have no Contact Quality Monitoring (CQM).
OVALPLATE Split Grounding Pads
(Diathermy Pads / Neutral Electrodes)
OvalPlate diathermy pads can be applied in any direction due to the oval design.
OVALPLATE Non-Split Grounding Pads
(Diathermy Pads / Neutral Electrodes)
OvalPlate diathermy pads can be applied in any direction due to the oval design.
Reusable Connection Cables
These durable connection cables are intended for use in multiple
procedures when appropriate disinfection procedures are followed.
Disposable Connection Cables
These single-use connection cables come already packaged with your prewired grounding pads.
Grounding Pads - English
From our patented TwinSafe design to our standard SwaroPlate offering, Nissha Medical Technologies Grounding (Diathermy) Pads are compatible with many electrosurgical generators.
Last Edited: 01/03/2024
Download Visit WebpageGrounding Pads - FR
From our patented TwinSafe design to our standard SwaroPlate offering, Nissha Medical Technologies Grounding (Diathermy) Pads are compatible with many electrosurgical generators.
Last Edited: 07/05/2024
Download Visit WebpageGrounding Pads - DE
From our patented TwinSafe design to our standard SwaroPlate offering, Nissha Medical Technologies Grounding (Diathermy) Pads are compatible with many electrosurgical generators.
Last Edited: 01/10/2022
Download Visit WebpageLas placas para electrocirugia - Spanish
Desde nuestro diseño patentado Twinsafe hasta nuestra oferta estándar de Swaroplate, las placas de NMT-HS son compatibles con muchos generadores electroquirúrgicos.
Last Edited: 01/07/2021